Yes, one can receive quite a painful bite from these inverters. The nominal operating voltage is roughly proportional to tube length, and the striking voltage is often about 50% higher than that. If a tube fails, the inverter periodically retries to start the tube, so the worst shocks paradoxically can occur when the tube is dark.
Post #10 by tomlee59
| Source Forum | 68kMLA |
|---|---|
| Category | Troubleshooting |
| Post Date | Wed, 23 Apr 2008 - 07:38 |
| Original URL | https://68kmla.org/bb/threads/ibook-clamshell-se-dim-screen.12893/ |
Post
Yes, one can receive quite a painful bite from these inverters. The nominal operating voltage is roughly proportional to tube length, and the striking voltage is often about 50% higher than that. If a tube fails, the inverter periodically retries to start the tube, so the worst shocks paradoxically can occur when the tube is dark.