Thread
Bad flyback transformers symptoms
What are some of the signs of a flyback transformer that is bad or going bad?
weird noises, and screen flickering out
tho those are the same basic symptoms of flyback to control (analog board in some machines)
more detail please
tho those are the same basic symptoms of flyback to control (analog board in some machines)
more detail please
Failing flybacks can occasionally cause the screen to go out of focus too, or slowly shift focus as it warms up.
Hmm..this sounds like the problems that were described to me. Screen flicker and buzzing sound. Good thing I have an analog board here with a good transformer attached. i'll just swap the whole thing out and worry about the actual transformer later.weird noises, and screen flickering out
tho those are the same basic symptoms of flyback to control (analog board in some machines)
more detail please
I have one that fizzes Nicola Tesla stylee (big blue arcs of HV) the sparks come from the triper (next to where the red HT cable is attached) to the scan coil cables, looks great in the dark. Kaput
excessive shorted turns in the primary of the flyback will cause the flyback, and the horizontal output transistor to run excessively hot. Keep this in mind as well.... loose cores will cause very high frequency noises.