Hello,
Thanks for the help everyone and I have solved the problem.
It was indeed the horizontal phase potentiometer, the glue holding it in position came off and then it moved during shipping I guess.
The reason I too thought it may be a capacitor is it would sometimes got backwards and forward between being unfolded and then folded. In the end it remained in the folded position and I thought okay, it seems like it may be more like a potentiometer issue.
Thanks for the help!
Thanks for the help everyone and I have solved the problem.
It was indeed the horizontal phase potentiometer, the glue holding it in position came off and then it moved during shipping I guess.
The reason I too thought it may be a capacitor is it would sometimes got backwards and forward between being unfolded and then folded. In the end it remained in the folded position and I thought okay, it seems like it may be more like a potentiometer issue.
Thanks for the help!