i have all 4 fixed, tested them all for 2 hours + /under full load for 30 min. (in a LC II)
The very last PSU i did, i was really scrounging for caps, i found some but these are not anything like what is on there, but it seems to work fine.
( last fixed psu got these values )
2 - 25v270uf ----> 16v 470uf
1 - 10v270uf ----> 16v 470uf
1 - 25v56uf ----> 25v 47uf
I am sure there was a method to their madness with the values they chose, but the caps I had laying around seem to work good.
The very last PSU i did, i was really scrounging for caps, i found some but these are not anything like what is on there, but it seems to work fine.
( last fixed psu got these values )
2 - 25v270uf ----> 16v 470uf
1 - 10v270uf ----> 16v 470uf
1 - 25v56uf ----> 25v 47uf
I am sure there was a method to their madness with the values they chose, but the caps I had laying around seem to work good.