First thing to check is whether the twelfth address bit is wired up in the SIMM sockets. Without that, the machine cannot physically address a SIMM larger than 4 MB. It's pin 24 in the socket.
Post #6 by trag
| Source Forum | Pushing the Classic II over the 10mb limit? — #6 |
|---|---|
| Category | Troubleshooting |
| Post Date | Fri, 25 Oct 2013 - 22:49 |
| Original URL | https://68kmla.org/bb/threads/pushing-the-classic-ii-over-the-10mb-limit.29145/ |
Post