We have proven that the caps have no impact on the tunneling. The tunneling is due to the seal of the LCD failing and moisture entering the display, which causes a parasitic capacitance that produces the effect seen. So far baking the LCDs that are contaminated helps somewhat. Its the best we've come up with to deal with this issue, its basically a problem with how they were made at the factory, an inherent defect.